Limits

Limits #

The rest of this section describes the architecture as designed. This page describes what the hardware underneath it cannot do.

Both are true at once, and the second is the easier one to forget, because the first reads like a datacenter: tenants, fabrics, authority boundaries, everything reproducible from code. The design philosophy already notes that Deevnet operates at a smaller scale than the platforms it borrows from β€” but scale is not the interesting constraint. Resilience is. Deevnet runs on consumer hardware with no redundancy anywhere in the critical path, and its recovery model is rebuild, not failover.

That is a deliberate trade, and a defensible one for a portable lab. It is written down here so that nobody reads the architecture and assumes otherwise.


No out-of-band management #

There is no IPMI, iDRAC, iLO, or remote KVM on any device in the estate.

When a device is misconfigured badly enough to lose its own management path, recovery is physical: a monitor and a USB keyboard, at the device. Different devices need different cables — mini DisplayPort for the core router, a DisplayPort→HDMI adapter for the hypervisors — which is a real operational cost at the moment you can least afford one. See Console Recovery.

The nearest substitute is Wake-on-LAN, declared per host (wol: true) and driven by playbooks/wol.yml. It is strictly one-way: it can wake a powered-down node, but it cannot power-cycle a hung one, reset it, or show you why it will not boot.

Nothing is clustered #

The two Proxmox nodes are standalone. There is no cluster, no quorum, no HA manager, and no automatic failover β€” a node that is down takes its guests with it until it comes back.

The consequence reaches further than availability. Without a cluster filesystem there is nothing enforcing VMID uniqueness across the substrate, so inventory does it instead:

The hypervisors are not clustered, so uniqueness across the substrate is enforced by the allocator (deevnet.mgmt playbooks/vm-identity.yml), not by Proxmox.

β€” mobile/group_vars/all/main.yml

That is the shape of most compensation here: something the hardware does not provide, rebuilt in software, in inventory, and in git.

Storage is local to the node that runs the workload #

Shared storage is documented as a planned addition, not a built one. VM disks live on the hypervisor’s own local-lvm-big-thin.

So even if the nodes were clustered there would be nothing to migrate to. Losing a hypervisor is a rebuild-and-restore, not a failover, and the recovery time is however long a rebuild takes.

Every network device is singular #

DeviceRedundancyIf it fails
Core router dv02cor002p01None β€” no CARP pairWhole site: routing, DNS, DHCP, firewall, egress
Access switch dv02acc001p01None β€” no second L2 pathWhole site’s wired connectivity
Access point dv02wap001p01NoneWireless only; wired is unaffected
Edge router dv02edg001p01NoneUpstream connectivity

Two of those take the entire site with them. This is also why a factory reset of the access switch is itself an outage rather than a repair β€” every port returns to VLAN 1 and the uplink trunk goes with it.

Consumer NICs, single-homed hosts #

The core router’s LAN and WAN are Realtek interfaces (re0, re1) β€” the opnsense_vlan_parent every VLAN sub-interface is built on.

Both hypervisors are single-NIC. On dv02hyp002p02, management, tenant transit and the fabric underlay all ride eno2 as VLAN sub-interfaces of a VLAN-aware vmbr0; dv02hyp001p01 is the same shape, which is why adding the MQTT broker to IoT Backend meant converting its switch port to a trunk rather than using a second port β€” there isn’t one.

There is no bonding, no LACP, and no NIC-level redundancy anywhere. A failed port, cable or NIC takes the host off the network.

The rebuild path is duplicated inside the thing it rebuilds #

The builder is not a single point of failure, and it is the one part of this page that mostly reads the other way. It is explicitly a role rather than a pet β€” “any suitable host can assume it via code β€” rebuilding or replacing the provisioner is expected” β€” and it is self-contained, portable and air-gapped capable, able to provision a site from nothing with no upstream dependency. That detachability is what makes rebuild rather than failover a credible strategy at all.

The duties are already spread. builder covers three hosts; artifact serving, bootstrap/PXE and workstation duties each cover two.

The limit is where the copies live. Two of the three are management-plane VMs on dv02hyp001p01 β€” inside the substrate they would be used to rebuild. For an everyday failure that duplication is real. For a substrate-level one it collapses to the third copy, the physical node you can detach and carry, and there is exactly one of those at the moment it matters most.

One production role is genuinely single-instance: dv00bld001p01 is the only network_controllers member, so the Omada controller has no second copy. That costs wireless and switch management rather than wireless or switching β€” adopted devices keep forwarding perfectly well without a controller.

**A caveat about deployment mode, not architecture.** In production the builder sits on the management segment, so automation runs from *behind* the policy it edits. The builder's own design allows it to be attached elsewhere β€” but that does not rescue a router with no rules loaded, which stays a [console job](/docs/runbook/recovery/console-recovery/core-router/).

One site has hardware #

home exists as an inventory skeleton with no hosts. There is no second site to fail over to, and no cross-site redundancy of any kind.

The mobile rack also travels, which makes availability partly a physical question: anything depending on the substrate stops when the rack leaves the building. That is not a fault, but it is a property worth stating β€” the EdS tenant records it plainly as “the lights stop when the rack leaves.”

Backups live on the thing being backed up #

OPNsense keeps its own configuration history on the router, which covers a configuration mistake but not a failed disk. No collection carries off-box backup automation; the manual download step in the segmentation prerequisites is the whole of the practice.


What holds this together instead #

The compensating controls are real, and they are the reason the trade works:

  • Everything is defined in code. Every device, service and segment is declared in inventory and applied by automation, so a lost device is rebuilt rather than repaired. Compute hosts are explicitly stateless.
  • Identity is allocated, not discovered. VMID β†’ MAC β†’ DHCP reservation β†’ DNS record is a chain derived from inventory, so a rebuilt host comes back as itself rather than as a new machine that happens to do the same job.
  • The provisioner is portable and replaceable. The builder carries its own artifacts, Git mirrors and boot infrastructure, provisions any site it is attached to, and is defined as a role any suitable host can assume. This is the mechanism behind rebuild, not failover β€” without it the rest of this page would be much harder to accept.
  • Recovery is documented per device. Console Recovery covers the router, the hypervisors, the switch and the AP, including which cable each needs.
  • The blast radius is understood. Network segmentation bounds what a compromised or misbehaving segment can reach, which matters more when there is no redundancy to absorb a mistake.

The honest summary: Deevnet is designed to be rebuilt quickly, not to stay up through a failure. Recovery time is a rebuild, and for a lab that is the right trade β€” as long as it is a choice rather than a surprise.

What it would take to lift each limit #

LimitWhat would change it
No out-of-band managementDifferent hardware β€” server boards with BMCs, or a networked KVM/serial console server
Nothing clusteredA third node for quorum, plus shared storage worth failing over to
Local storage onlyThe shared storage already scoped in Substrate Storage
Single core routerA second appliance and a CARP pair, with the state sync that implies
Single switch / single-homed hostsA second switch, second NICs, and LACP or MLAG
Rebuild path collapses to one physical nodeA second detachable builder β€” the provisioner is already a role, so this is hardware rather than design
Single Omada controllerA second controller instance, or accepting that device management is best-effort
One populated siteHardware in home, which the inventory skeleton is already shaped for
On-box backups onlyOff-box config backup automation β€” the smallest item on this list, and the one with the best return