CHG-0006: Access Switch Firmware Upgrade

CHG-0006: Access Switch Firmware Upgrade #

Date2026-09-16
Change typeUpgrade
ClassificationDisruptive — the reboot drops every wired path on site
StatusComplete, 2026-09-16. The switch runs 1.20.24 from image1.bin, with 1.20.1 kept in image2.bin as the rollback. The configuration came through unchanged and matches inventory, and Ansible connects. STP is still disabled. LLDP came up enabled under the new default and was kept on deliberately; it is now declared in inventory.
Window2026-09-16, one operator window. The operator was on site and reached the builder through the travel router. The switch was down from 08:15:32 to 08:17:11 EDT, about 100 seconds.
Sitemobile
SystemsAccess switch dv02acc001p01 (SG2218, hardware 1.20)
AutomationFirmware mirrored by inventory #23; procedure in docs #29 and #70. LLDP declared by net #21 (switch_lldp) and inventory #33.
RiskHigh. The switch reboot takes the builder, the controller and Ansible offline with everything else.
Related changesCHG-0004 — this was its phase 2 until 2026-09-11
Related incidentsNone
Related runbooksAccess Switch → Firmware upgrade; Operator Access; Important URLs

Summary #

The access switch ran firmware 1.20.1, from January 2024. Current for its hardware is 1.20.24, from May 2026: one hop, with no minimum prior version and nothing irreversible. This change is the firmware only. The switch stays standalone, configured by switch_vlans. Adopting it into the controller is a later change under ADR-0009.

It was phase 2 of CHG-0004 until the AP work was split out to go first.

Goal #

  • The switch runs 1.20.24 in one image slot, with 1.20.1 kept in the other as the rollback.
  • Its configuration is unchanged, and Ansible still connects.
  • STP and LLDP are in a state that was chosen rather than inherited from new defaults.

Scope #

In scope: the switch’s firmware. Out of scope: adopting it into Omada, and any configuration change.

Risk and impact #

RiskGuard
The reboot drops every wired path, the builder’s included — the controller, Ansible and the browser used for the uploadUpload without auto-reboot, so the outage starts when the operator chooses. The hypervisors are not clustered, so nothing fences.
There is no console port. The SG2218 has LEDs, a reset button, RJ45 ports and SFP slots, and nothing else ( installation guide).The way back from a bad state is the dual image (see Undo) or the reset button. After a reset, nothing on site hands out an address on VLAN 1, so the laptop needs a static 192.168.0.2/24 to reach the switch at 192.168.0.1.
Automation loses the switch: it is reached over legacy SSH key exchange, and 1.20.4 (OpenSSL) and 1.20.19 (SSH fix) are where that could changeVerification leads with “does Ansible connect”; 1.20.1 stays on flash as the rollback
New defaults come up under an unchanged config: STP is on by default from 1.20.9, LLDP from 1.20.4Baseline recorded below: both disabled today

Prerequisites #

  • Firmware 1.20.24 mirrored and pinned by sha256; it matched on 2026-09-10.
  • Operator on site, connected to the builder through the travel router rather than the switch, per Operator Access. The SSH session survives the reboot, and its tunnel carries the switch’s web UI (https://localhost:8443) for the upload. Backup: a laptop on the operator port gi1/0/2 ( Operator Access → Backup). That path goes through the switch, so it’s fine for the backup and the upload, but it drops at the reboot along with everything else.
  • The .bin downloaded to the laptop beforehand, with sha256 a01034c5409bd14c9066db857d192807bdfe85788472ed12bb5778159c7a4e0d. That is the file inside the pinned zip, checked on 2026-09-16.
  • Vault decrypted, so Ansible can verify the switch before and after.
  • show system-info, show image-info and the running config captured on the day. Not done. A configuration backup was taken from the web UI, but not the CLI captures. The config after the upgrade was checked against inventory instead; see Outcome.

Baseline, 2026-09-10 #

Firmware1.20.1 Build 20240115 in image2.bin (boots); image1.bin holds the factory 1.1.3
STPSpanning tree is disabled
LLDPLLDP Status: Disabled
Management10.20.99.10 on VLAN 99; OPNsense also reserves 5c:62:8b:0c:40:ec10.20.99.10

Procedure #

Follow Access Switch → Firmware upgrade:

  1. Record where it starts — capture system info, image info and the running config.
  2. Upload into the backup image from https://10.20.99.10 (https://localhost:8443 through the tunnel) — the .bin, with the auto-reboot box unchecked.
  3. Boot from it — set the next startup image, then reboot at a moment of the operator’s choosing. Before the reboot, read Keeping the builder online.
  4. Verify — see below.

Keeping the builder online during the reboot #

The builder has two uplinks. Only one of them goes through the switch.

InterfaceAddressPathRole today
enp4s010.20.99.95/24, staticSwitch gi1/0/16 → OPNsense 10.20.99.1Preferred default route and preferred DNS (ipv4.dns-priority 10)
enp1s0192.168.8.x, DHCPTravel router dv02edg001p01 at 192.168.8.1, not through the switchSecond default route (higher metric); DNS 192.168.8.1, not used while enp4s0 is up

On 2026-09-16, enp1s0 was checked on its own: it pings 1.1.1.1, reaches https://api.anthropic.com over HTTPS, and 192.168.8.1 resolves public names. An operator session to the builder over the travel router’s wireless doesn’t touch the switch, so it survives the reboot. See Operator Access.

What happened on 2026-09-16: when the switch rebooted, enp4s0 lost its link, and in the same second NetworkManager logged set 'enp1s0' (enp1s0) as default for IPv4 routing and DNS. New connections from the builder went out through enp1s0. A connection that is already open over enp4s0 doesn’t move with it. When the switch returned about 100 seconds later, enp4s0 connected again on its own (autoconnect is on), and DNS moved back to 10.20.99.1.

The default route did not move back. Neither connection pins its route metric, so on reconnecting enp4s0 was given metric 102, behind enp1s0’s 101. Internet traffic from the builder stayed on the travel router. Traffic to the site VLANs was unaffected, because it uses the specific 10.20.0.0/16 and 10.10.0.0/16 routes through enp4s0. Pinning the metrics is a follow-up.

Check it during the outage:

ip route get 1.1.1.1              # expect: via 192.168.8.1 dev enp1s0
resolvectl status | grep -E 'Link|Current DNS|Default Route'   # expect enp1s0 as the default route
getent hosts api.anthropic.com    # public names still resolve

If it doesn’t fall back (the route still points at enp4s0, or names don’t resolve), force it:

sudo nmcli con down enp4s0        # routes and DNS move to enp1s0
# ... wait until the switch has booted ...
sudo nmcli con up enp4s0          # the switch path is preferred again
ping 10.20.99.10

enp4s0 is also the builder’s only route to the switch and every site VLAN. While it’s down, ping 10.20.99.10 can’t tell you the switch is back. Watch the switch’s LEDs, or retry nmcli con up enp4s0 until it succeeds, then ping. Bring it back up before verifying.

Verification #

  • Version and image slots: 1.20.24 boots, and 1.20.1 is in the other slot.
  • Ansible connects.
  • STP and LLDP compared with the baseline above.
  • The running config compared with step 1.
  • The reachability pings.
  • One run of switch-vlans.yml.

Undo #

1.20.1 stays on flash. Point the boot configuration back at it and reboot — Access Switch → Rollback. The configuration is kept.


Outcome #

Done on 2026-09-16, in one operator window.

Upload and reboot. The operator reached the builder over the travel router and uploaded the .bin through the tunnel. The “reboot using the backup image” box was checked, which departs from the procedure: the switch rebooted straight after the write, not at a separately chosen moment. It did no harm. The switch came up on 1.20.24 in image1.bin, replacing the factory 1.1.3, and set image1.bin as Next Startup Image too, so the Boot Config step was already done. image2.bin still holds 1.20.1. The link was down from 08:15:32 to 08:17:11 EDT.

Verification.

CheckResult
Version and image slots1.20.24 Build 20260509 Rel.23533. Current and next startup: image1.bin (1.20.24). Backup: image2.bin (1.20.1).
Ansible connectsYes. The legacy SSH settings still work on 1.20.24.
STPSpanning tree is disabled, the same as the baseline
LLDPEnabled; the baseline was Disabled. The 1.20.4 default came up under an unchanged config, as expected. Kept on deliberately, for mapping neighbours port by port, and declared as switch_lldp: true (net #21, inventory #33). With the declaration in place, --tags mgmt finds the switch already matching and changes nothing.
Running configNo capture was taken before the upgrade, so it was checked against inventory instead. Every declared VLAN name, all four trunks (untagged, tagged and PVID), all four access ports, the hostname, the management address and the default gateway match. The undeclared ports are at defaults.
ReachabilityThe switch, OPNsense, the AP, both hypervisors, the Omada controller, the MQTT broker (10.20.35.20, through a tagged trunk) and the gateways of VLANs 10, 25, 30 and 35 answered. The IoT Pis did not, because their ports gi1/0/3 and gi1/0/14 have no link: nothing is plugged in or powered.
switch-vlans.ymlFailed twice, then passed twice. The first two runs, about 10 to 15 minutes after boot, each hit a 30-second command timeout near the end of the VLAN commands (name blackhole, then vlan 999). The next two runs, one with -vvvv and one at normal speed (66 s), finished with failed=0. The running config was identical before and after all four runs, and startup matches running. The command grammar still parses on 1.20.24. The timeout is recorded as intermittent: the switch may have still been settling after boot, but that isn’t established.

No re-provisioning was needed. The configuration survived the upgrade unchanged, and the playbook runs applied nothing that wasn’t already there.

Noticed in the running config. With no capture from before the upgrade, none of these can be attributed to the new firmware:

  • telnet enable is set.
  • NTP is still at factory values: system-time ntp UTC+08:00 with two public servers. The switch clock read about 12 hours ahead of the builder.
  • gi1/0/5 has a link but isn’t declared in inventory, so whatever is on it is in VLAN 1, which isn’t routed.
  • gi1/0/13 and gi1/0/16 carry no switchport general allowed vlan 1. The other declared ports keep their default VLAN 1 membership. Inventory says nothing either way.

Follow-ups #

  • Confirm whether 1.20.17 and later force a password change at first login after a reset. That can only be seen when the switch is reset, which the eventual adoption change will do.
  • Move the switch firmware procedure into Lifecycle. It sits in the console-recovery page today.
  • Merge net #21 and inventory #33, which declare LLDP.
  • Pin the builder’s route metrics (for example enp4s0 100, enp1s0 200), so the switch path wins again after an outage.
  • Find the cause of the intermittent switch-vlans.yml command timeouts seen shortly after boot.
  • Decide on telnet enable. If it goes, declare it.
  • Set the switch’s NTP servers and time zone from inventory.
  • Identify what is on gi1/0/5, and declare the port or unplug it.
  • Make VLAN 1 membership consistent across declared ports, and declare it.
  • Before the next switch change, take the CLI captures. This change had to verify against inventory, because there was no capture to compare with.