Access Switch #
Recovering dv02acc001p01 when it can no longer be reached at 10.20.99.10 — by discarding
its configuration and rebuilding it from inventory.
The switch’s whole configuration is declared: VLAN database, trunks, access ports, hostname
and default gateway all come from host_vars/dv02acc001p01.yml and are applied by one
playbook. That makes a factory reset a legitimate recovery tool rather than a last resort —
there is nothing on the switch worth preserving that is not already in git.
**A factory reset takes the whole site down until the playbook has run.** Every port returns to default VLAN 1, which means the uplink trunk to `dv02cor002p01` is gone, inter-VLAN routing stops, and every host on this switch loses its segment. Do this deliberately, with time set aside — not as a quick thing to try.
Try this first #
The SG2218 has no console port — only LEDs, the reset button, RJ45 ports and SFP slots, per
its
installation guide.
So the question is whether it still answers on its management address from anywhere: the
builder, or a laptop on the operator port gi1/0/2. If it does, fixing the specific fault over
the network is faster and far less disruptive than a reset. The usual culprit after a trunk
change is a native VLAN mismatch on the uplink — see
troubleshooting.
Reset only when the switch is unreachable by every route, or its configuration is unknown.
What you need #
| Access | Physical, to press and hold the reset button. |
| A laptop | To reach the switch on its factory address before it is back on the network. |
| A patch cable | Direct into any switch port. |
| Device | dv02acc001p01, TP-Link Omada SG2218, hardware 1.20 |
| Firmware | 1.20.24 Build 20260509 since 2026-09-16 (
CHG-0006), in image1.bin; 1.20.1 kept in image2.bin. See
firmware upgrade. |
| Managed address | 10.20.99.10, gateway 10.20.99.1 |
| Uplink to router | gigabitEthernet 1/0/1, native VLAN 999 |
| Builder port | gigabitEthernet 1/0/16, access VLAN 99 |
| Declared by | switch_ports in mobile/host_vars/dv02acc001p01.yml |
| Applied by | ansible-collection-deevnet.net, playbooks/switch-vlans.yml |
1. Reset #
Press and hold the reset button until the switch restarts into factory defaults.
2. Bootstrap it back onto the network #
This is the step automation cannot do for you. Ansible reaches the switch at the address derived from inventory (10.20.99.10), and a factory-reset switch is not there yet.
Connect your laptop directly to a switch port and give yourself an address on the switch’s default subnet — the same manoeuvre the AP procedure uses:
sudo ip addr add 192.168.0.2/24 dev <iface>
**Confirm the factory address on the device label before assuming it.** TP-Link Omada switches commonly return to `192.168.0.1/24`, but this varies by model and firmware. Once confirmed for this switch, record it in this table so the next person does not have to guess. **A reset switch returns to `admin`/`admin`**, per the label and TP-Link's current guides. Firmware 1.20.17's release note says it *"remove[s] default username and password"* from the initialization process. That most likely means first login forces a password change, not that the defaults are gone — confirm on the device after the upgrade. If you are asked to set credentials, use `vault_switch_user` / `vault_switch_password` from `group_vars/switches`, since that is the account Ansible logs in with. From 1.20.4, standalone mode also starts with HTTP off: browse `https://`.
In the switch’s web UI or CLI, set just enough for Ansible to take over:
- the management IP
10.20.99.10/24on the management VLAN - the default gateway
10.20.99.1 - the uplink port
gigabitEthernet 1/0/1trunking to the router
Everything else is left alone — the playbook writes it.
3. Reapply the declared configuration #
cd ansible-collection-deevnet.net
ansible-playbook playbooks/switch-vlans.yml
This restores the VLAN database, the trunk ports and their native VLANs, the access port
assignments, the hostname and the default gateway, and commits to flash via the
write memory handler.
**This is the standalone path.** Once the switch is adopted into the Omada controller (`switch_management: omada`), the controller applies this same inventory, and `switch-vlans.yml` refuses to run against the switch. It becomes break-glass: for when the controller cannot be used, after the switch has been returned to standalone, with `-e switch_vlans_break_glass=true`. See [ADR-0009](/docs/architecture/decisions/0009-network-device-config-ownership/).
**`--check` is not useful here.** `ansible.netcommon.cli_command` accepts only `show` commands in check mode, so a dry run fails on every configuration line rather than previewing it. See [Change Management](/docs/runbook/change-management/).
4. Verify #
From the switch:
show vlan brief
show interface switchport gigabitEthernet 1/0/1
show running-config
From the builder:
ping -c1 10.20.99.10 # the switch itself
ping -c1 10.20.99.1 # the router, through the restored trunk
ping -c1 10.20.30.11 # a host on another segment
Every VLAN in
the network reference should be present,
and gigabitEthernet 1/0/1 should be trunking with native VLAN 999.
5. Re-adopt in Omada #
A factory reset drops the switch out of the Omada controller. Re-adopt it at
https://10.20.99.95:8043, following
Omada device adoption.
Adoption is management only — the switch forwards traffic correctly whether or not Omada has claimed it, so this is the last step rather than a prerequisite.
If this is replacement hardware rather than the same switch, check its firmware before adopting. A reset does not change firmware, but a new unit arrives on whatever it shipped with — see firmware upgrade.
Firmware upgrade #
This is not a recovery step. It is a planned change, made while the switch is reachable and its configuration is intact. The upgrade to 1.20.24 was done under CHG-0006 on 2026-09-16. Nothing is reset, the configuration is kept, and the playbook does not need to run.
| Hardware | SG2218 1.20, per show system-info. A label reading V1.26 takes the same firmware. |
| Running | 1.20.24 Build 20260509 in image1.bin, since 2026-09-16. image2.bin holds 1.20.1, the rollback. Before that, 1.20.1 booted from image2.bin and image1.bin held the factory 1.1.3. |
| Target | 1.20.24 Build 20260509 |
| Route | One hop. None of the eight V1.20 builds since declares a minimum prior version or is flagged irreversible. |
| File | http://artifacts.mobile.deevnet.net/firmware/sg2218/, pinned in artifacts_to_fetch |
Do this before the switch is adopted into Omada, not after. The controller-facing code is what changed most: 1.20.14 is the first build TP-Link align with controller 6.x, and 1.20.17 fixed security vulnerabilities in the switch’s interaction with the controller. 1.20.24 recommends controller 6.2.0 or later; this site’s controller has run 6.3.0.45 since 2026-09-10.
**The reboot takes down every wired path on the site, including the builder's.** The browser you uploaded from, Ansible, the Omada controller and the route to every segment all go with it until the switch is back. The hypervisors are not clustered, so nothing fences: guests keep running, just unreachable. The AP loses its uplink. Set time aside. The switch has no console port, so the way back from a bad boot is the other image slot ([Rollback](#rollback)), or the reset button and a laptop on a static `192.168.0.2/24`.
1. Record where it starts #
From the builder (decrypt the vault first, or add --ask-vault-pass):
cd ansible-collection-deevnet.net
ansible dv02acc001p01 -m ansible.netcommon.cli_command -a "command='show system-info'"
ansible dv02acc001p01 -m ansible.netcommon.cli_command -a "command='show image-info'"
ansible dv02acc001p01 -m ansible.netcommon.cli_command -a "command='show running-config'" \
> ~/dv02acc001p01-running-config-1.20.1.txt
The switch holds two images. show image-info shows which one boots and which is the backup.
The upload is written into the backup slot, so whichever slot holds 1.20.1 now is the rollback.
On 2026-09-10 that was image2.bin. The backup, image1.bin, held the factory 1.1.3, which
the upload replaces; nothing is lost with it.
2. Upload into the backup image #
Download the .bin from the artifact server to the machine running the browser. From the
builder, browse https://10.20.99.10 directly — the builder is on the management segment with
the switch, so no tunnel is needed.
Under SYSTEM → System Tools → Firmware Upgrade, choose
SG2218v1_en_1.20.24_[20260509-rel23533]_up.bin and leave “Reboot the switch using the
backup image after upgrading is completed” unchecked. With it unchecked, the upload writes the
backup image and the switch keeps running 1.20.1. A failed write then costs nothing, and the
outage happens when you choose rather than as a side effect of the upload. The write takes
several minutes; leave the switch alone while it runs.
If the box is checked by mistake, nothing is lost, but the outage starts as soon as the write
finishes. On 2026-09-16 the switch then rebooted into the new image and made it the Next
Startup Image as well, so step 3 was already done. Confirm that with show image-info rather
than assuming it.
3. Boot from it #
Under SYSTEM → System Tools → Boot Config, the image table should now show 1.20.24 in the backup image. If it does not, stop here — nothing has changed yet. Otherwise set that image as Next Startup Image and the current one as Backup Image, then Apply.
Then use SYSTEM → System Tools → System Reboot, with Save the current configuration before
reboot checked. Running and startup config should already match, because the playbook ends in
write memory, so the save should add nothing. It is TP-Link’s instruction and does no harm.
Wait for it from the builder with ping 10.20.99.10.
4. Verify #
Rerun the show system-info and show image-info commands from step 1. The version should
read 1.20.24 Build 20260509, and the backup image should hold 1.20.1.
The most important check is that those commands run at all. Ansible reaches this switch over SSH with legacy key exchange (see the options in post-migration), and two years of builds — including an OpenSSL update in 1.20.4 and an SSH stability fix in 1.20.19 — are where that could change.
Then compare the running config with step 1’s capture; expect only additions. Two builds in
between change defaults: spanning tree is on by default from 1.20.9, and LLDP from 1.20.4. A
setting that was never written to config, because it matched the old default, is the kind that
can come up under a new one. Check show spanning-tree active in particular. If STP is now on,
decide deliberately whether it stays, and declare that decision either way instead of
inheriting it.
Run the recovery verification pings, then the playbook once:
ansible-playbook playbooks/switch-vlans.yml
It applies nothing that is not already declared. It is also the only test that the role’s command grammar still parses on the new firmware, and that is better learned now than in the middle of a recovery.
Rollback #
1.20.1 is still on flash, in the backup image. In Boot Config, set it as Next Startup Image, Apply, and reboot. There is no re-flash and no download. The configuration is kept, although anything configured through a feature newer than 1.20.1 will not apply.